Conductor & OPGW

Cable, Conductor & OPGW

Silverstone supplies the complete overhead-line conductor package — AAC, AAAC and ACSR bare conductors, XLPE power and aerial bundled cables to 26/35 kV, and OPGW/ADSS optical ground wire with matched fittings. Sourced from qualified Chinese plants, delivered on export drums with routine test reports, and engineered to your grid code and span-tension-sag design.

Key Specifications

Product scopeBare overhead conductors · LV/MV power & aerial cables · OPGW / OPPC / ADSS
Conductor typesAAC (JL/LJ) · AAAC (JLHA1/JLHA2) · ACSR (LGJ, JL/G1A) · thermal-resistant aluminum alloy · hard copper (TJ)
ACSR range10/2 – 800/100 mm² (aluminum/steel)
Aluminum stranded range16 – 800 mm²
Copper stranded (TJ)16 – 400 mm²
XLPE power cable3.6/6 kV – 26/35 kV, 25 – 800 mm², single- and three-core, armored options
OPGW typical24 – 48 fibers per SUS tube · Ø 9.6 – 22.1 mm · RTS 60 – 278.5 kN · short-circuit 12 – 714 kA²·s
Reference standardsGB 1179 · IEC 60794-4 · IEEE 1138 / P1222 · DL/T 832 · ASTM B416 · IEC 61232 / 60889
Sourcing baseSuzhou Industrial Park, Jiangsu, China

Typical configurations shown. Final ratings, dimensions and test reports are confirmed per project datasheet — include your specification with the inquiry. Download brochure (PDF) →

Typical Applications

Overhead transmission linesDistribution feedersUtility telecom backbone (OPGW)Substation bus & gantriesRailway electrificationRural electrification

Frequently Asked Questions

What information do you need to quote conductors or OPGW?
Conductor type and code (e.g. ACSR 240/30), applicable standard, quantity in km or tons, drum/length requirements and destination port. For OPGW, add fiber count and type, rated tensile strength (RTS), short-circuit capacity and line voltage. We return a priced offer with lead time within 24 hours on working days.
Which standards do your conductors and optical cables comply with?
Bare conductors are supplied to GB 1179 classes or to IEC-equivalent constructions on request; aluminum-clad steel wires follow ASTM B416 and IEC 61232. OPGW and ADSS follow IEC 60794-4, IEEE 1138 / IEEE P1222 and DL/T 832 / GB/T 7424.4. Export orders are produced to IEC or to the customer's specification.
Can you design an OPGW for our transmission line?
Yes. Provide system voltage, fiber count, span-tension-sag requirements, weather loads (wind speed, ice thickness) and tower data; our partner engineers return a structure design with diameter, weight, RTS, DC resistance and short-circuit capacity for approval before production.
Do you supply OPGW hardware and fittings together with the cable?
Yes. Dead-end fittings, suspension clamps, vibration dampers, joint boxes, down-lead clamps and earthing wires for OPGW and ADSS are quoted with the cable so the whole line package arrives matched.